Cannot open file (/var/www/vhosts/aprendtech.com/httpdocs/wordpress/wp-content/backup/.htaccess)Cannot write to file (/var/www/vhosts/aprendtech.com/httpdocs/wordpress/wp-content/backup/.htaccess) AprendBlog » Physics


Apr 01 2013

Optimal SNR versus tube voltage

Tag: NearOptimalPaper,Physics,softwareadmin @ 12:29 pm

In this post, I continue the discussion of my paper, “Near optimal energy selective x-ray imaging system performance with simple detectors.” I summarized many of the theoretical formulas in my last post. Here, I will discuss the formulas for the SNR with x-ray tube spectra with different voltages and different object thicknesses. I will present code to reproduce Figs. 7-9 of the paper. The results show that the energy-selective detectors have SNR that is approximately 4 times larger than the SNR with energy-integrating detectors, the detectors used in almost all conventional medical x-ray systems.

more →


Mar 12 2013

Summary ebook available

I have prepared an ebook that compiles and organizes the posts in this blog to today’s date. You can access it by sending me email:
Energy-selective x-ray imaging and other topics.

I plan to update the book regularly and I will post an entry to the blog when an updated version is available.


Feb 02 2013

Status of discussion of “Near optimal …” paper

Tag: NearOptimalPaper,Noise,Physicsadmin @ 4:51 pm

In this post I will summarize where I stand in the discussion of my paper, “Near optimal energy selective x-ray imaging system performance with simple detectors.” You will find it useful to download a free copy of the paper to follow along with this discussion.

more –>;


Dec 06 2012

The NKQ detector

Tag: Noise,Physicsadmin @ 2:24 pm

The NKQ detector introduced in my paper[Alvarez2010] is a generalization of the NQ where instead of just counting the photons we use pulse height analysis (PHA) to separate the photons into K bins depending on their energies and simultaneously measure their total energy. This gives performance similar to PHA with the number of bins plus one so it may be easier to implement. As with the NQ detector, the integrated energy Q can be used in regions where high count rate leads to excessive pulse pileup.

more –>;


Sep 10 2012

NQ detector SNR

Tag: Noise,Physics,softwareadmin @ 10:23 am

In this post, I continue to discuss the results in my paper “Near optimal energy selective x-ray imaging system performance with simple detectors[Alvarez2010].” The paper discusses fundamental limits on the signal to noise ratio of x-ray detectors with energy spectrum information. It also describes how we can design practical systems with low energy resolution detectors whose performance gets close to the optimal limit. The paper uses statistical detection theory to show that the performance depends on the signal to noise ratio (SNR) and derives a formula (see this post) to compute the SNR as a function of the detector spectral response and noise properties. In this post, I use the formulas for the NQ (simultaneous photon counts and integrated energy) detector data statistics from my last post to compute the SNR. We can use the formulas to show that the NQ signal (almost) always has a larger SNR than the N and Q individual signals. The SNRs are equal if the spectrum has zero-width.

more –>;


Feb 20 2012

SNR with PHA vs. number of bins

Tag: Noise,Physics,softwareadmin @ 6:43 pm

In this post, I will discuss the signal to noise ratio (SNR) of a photon counting detector with pulse height analysis (PHA). I will show that it approaches the ideal full-spectrum SNR as the number of bins gets large. I will also show that we can get quite close to the ideal value even with a small number of bins, which was one of the main points in my paper.

I will begin by re-visiting a result from my last post that the Cramèr-Rao lower bound (CRLB) with multivariate normal log of photon count data assuming a constant covariance is nearly equal to the accurate matrix that includes the variation of the covariance. The derivation becomes problematic with a large number of bins since the mean value in each bin may be small enough so the normal approximation to the counts is not valid. I will show an alternate derivation that uses the Poisson model of the count data, which is valid for small counts. The result is formally the same as with the normal approximation so the CRLB formula can be applied for any number of bins. This result is new and was not included in my paper.

more –>;


Jan 30 2012

A-space covariance from x-ray detector noise

Tag: Noise,Physics,softwareadmin @ 10:47 am

My last post showed that detection performance is determined by the signal to noise ratio (SNR). I derived a formula for the SNR with multispectral measurements, which depends on the covariance of the A-space data. This post shows how to compute the A-space covariance from the x-ray data noise and the effective attenuation coefficient matrix. In general, this depends on the type of estimator used so instead I will use the Cramèr-Rao lower bound (CRLB), which is the minimum covariance for any unbiased estimator. This gives a general result independent of the specific estimator implementation. I will show that the constant covariance CRLB is sufficiently accurate for our purposes. These results will allow us to compute signal to noise ratios for limited energy resolution measurements that are directly comparable to the Tapiovaara-Wagner[Tapiovaara1985] optimal SNR with complete energy information.

more –>;


Jan 24 2012

Detection theory with A-space data

Tag: Noise,Physics,softwareadmin @ 11:36 am

In my last posts I discussed the background for applying statistical detection theory to x-ray imaging. In this post, I will show how to incorporate the A-space description into the model. This will lead me to discuss the effect of the basis set functions on the approximation or representation error of the attenuation coefficients of body materials. I will show that there are optimal functions that minimize the error but that other basis functions, such as the attenuation coefficient functions of different materials, do not lead to substantially larger errors. Once the A-space description is in the model, we can derive a signal to noise ratio that is directly comparable to the Tapiovaara-Wagner SNR[Tapiovaara1985] and we can compare the SNR with limited energy resolution to the ideal with complete spectral information.

more –>;


Dec 20 2011

Normal probability models for x-ray measurements

Tag: Noise,Physics,softwareadmin @ 11:04 am

In my last post, I described a three part model used in statistical signal processing: (1) an information source produces outputs described by a finite dimensional vector, (2) a probabilistic mapping between the source outputs and the measured data, and (3) a receiver or processor that computes an estimate of the source output or makes a decision about the source based on the data. I showed that in x-ray imaging the information is summarized by the A vector whose components are the line integrals of the coefficients in the expansion of the x-ray attenuation coefficient. The basis set coefficients a(r) depend on the material at points r within the object and the line integrals Aj = aj(r)dr are computed along a line from the x-ray source to the detector. I then showed the rationale for a linearized model of the probabilistic mapping from A to the logarithm of the detector data L

(1) δLwith_noise = MδA + w

In this post, I will try to convince you that the multivariate normal is a good model for the noise w. This will lead me to discuss tests for normality including probability plots and statistical tests based on them such as the Shapiro-Wilk test[4] (available online) for univariate data and Royston’s test[3] for multivariate data.

more –>;


Nov 16 2011

statistical estimation and hypotheses testing in x-ray imaging

Tag: Noise,Physics,softwareadmin @ 9:56 am

The last two articles discussed the use of energy information to increase the SNR of x-ray imaging systems. They assumed that the attenuation coefficient is a continuous function of energy and that the energy spectrum is measured with perfect resolution. But we know from my posts here, here, here, and here that the attenuation coefficient can be expressed as a linear combination of two functions of energy. In addition, as I discussed in my posts about deadtime, the extremely high count rates required for medical x-ray systems severely limit the energy resolution and the complexity of the signal processing.

My paper “Near optimal energy selective x-ray imaging system performance with simple detectors”, which is available for free download here, discusses the use of the two-function decomposition in the signal processing. By transforming the problem from infinite to finite dimensions, the decomposition allows us to get near ideal SNR using low energy-resolution measurements, which may be possible with high speed photon counting detectors.

more –>;


« Previous PageNext Page »